Technical Data Sheet : DC COMPRESSOR R600a Series
Working condition limit:R600a
Model | Power supply (V/rpm) | Displacement (cm3) | Cooling Capacity(W) | COP (W/W) | Motor Type |
DL30C | 12~24/2000 | 3.1 | 32 | 1.20 | BLDC |
12~24/3500 | 55 | 1.25 | |||
DL35C | 12~24/2000 | 3.5 | 39 | 1.35 | BLDC |
12~24/3500 | 70 | 1.35 | |||
VDL30C | 12~24/2000 | 3.1 | 32 | 1.20 | BLDC |
12~24/3500 | 55 | 1.25 | |||
100-240/2000 | 32 | 0.90 | |||
100-240/3500 | 55 | 1.05 | |||
VDL35C | 12~24/2000 | 3.5 | 39 | 1.35 | BLDC |
12~24/3500 | 70 | 1.35 | |||
100-240/2000 | 39 | 1.05 | |||
100-240/3500 | 70 | 1.15 | |||
DK52C | 12~24/2000 | 5.2 | 55 | 1.50 | BLDC |
12~24/3500 | 100 | 1.60 | |||
VDK52C | 12~24/2000 | 5.2 | 55 | 1.50 | BLDC |
12~24/3500 | 100 | 1.55 | |||
100-240/2000 | 55 | 1.35 | |||
100-240/2000 | 100 | 1.40 | |||
DK70C | 12~24/2000 | 7.0 | 75 | 1.50 | BLDC |
12~24/3500 | 136 | 1.45 | |||
DK90C | 12~24/2000 | 9.0 | 105 | 1.50 | BLDC |
12~24/3500 | 175 | 1.45 |
Test conditions | ASHRAE According to ASHRAE |
Evaporating temperature | -23.3℃ |
Condensing temperature | 54.4℃ |
Subcooling temperature | 32.2℃ |
Suction temperature | 32.2℃ |
Ambient temperature | 32.2℃ |
Max ambient temperature | 55[℃] |
Evaporation temperature range | -35~-15[℃] |
Working voltage range | 12/l24V[DC],100-240V[AC] |
Max discharge pressure | 0.98[Mpa] gauge pressure |
Max allowable housing temperature | 85[℃] |
max pressure housing endured | 3.5 [Mpa] gauge pressure |
Low voltage start | 0.5/0.5Mpa ( gauge pressure) 10.8V/22.7V[DC];100V[AC] |